Search results for "Olecranon fracture"
showing 5 items of 5 documents
Functional results after operative treatment of olecranon fractures.
2004
In a retrospective, nonrandomized study, we reviewed our experience with the operative treatment of olecranon fractures to find out which factors correlate with subjective complaints and functional outcome. A total of 95 consecutive olecranon fractures were operatively treated in our level I trauma institution between March 1, 1992 and March 1, 2000. Medical charts and radiographs of all patients were evaluated. Three patients died, 23 were lost to follow-up. Fifty-eight of 69 available patients (84.0%) were reviewed clinically and/or radiologically after a mean time interval of 36 months. Fracture type, fracture classification, associated lesions, technical correctness of osteosynthesis, a…
Olecranon fractures in adults: factors influencing outcome.
2003
In a retrospective, non-randomized study, we reviewed our experience with the operative treatment of olecranon fractures to find out which factors correlate with subjective complaints and functional outcome. A total of 95 consecutive olecranon fractures were operatively treated in our level I trauma institution between 1 March 1992 and 1 March 2000. Medical records and X-rays of all patients were evaluated. Three patients died, 23 were lost to follow-up. Fifty-eight of 69 available patients (84.0%) were reviewed clinically and/or radiologically after a mean time of 36 months. Fracture type, fracture classification, associated lesions, technical correctness of osteosynthesis, age and comorbi…
New intramedullary locking nail for olecranon fracture fixation--an in vitro biomechanical comparison with tension band wiring.
2010
The aim of this study was to determine the difference in displacement of a newly designed intramedullary olecranon fracture fixation device compared with multifilament tension band wiring after 4 cycles and 300 cycles of dynamic continuous loading.In eight pairs of fresh-frozen cadaver ulnae, oblique olecranon fractures were created and stabilized using either newly designed intramedullary olecranon nail or multifilament tension band wiring. The specimens were then subjected to continuous dynamic loading (from 25 N to 200 N) using matched pairs of cadaveric upper extremities. The Wilcoxon test was used to determine statistical differences of the displacement in the fracture gap.After 4 cycl…
Dynamic biomechanical analysis of different olecranon fracture fixation devices--tension band wiring versus two intramedullary nail systems: an in-vi…
2007
Abstract Background. The aim of this study was to develop a test-setup with continuous angle alteration to imitate joint motion for the evaluation of 3 different olecranon fracture fixation devices. Methods. Twenty-one fresh cadaver upper extremities underwent olecranon fracture by the means of transverse osteotomy and received 3 different fixation systems. Group 1: Tension band wiring according to Weber. Group 2: XS-nail with 9 holes, all locked with 2 mm threaded K-wires. Group 3: Olecranon Nailing System with 90 mm length, locked with 2.7 mm screws, a variable angle locking hole for the proximal fragment and a proximal locking end cap. The servo-pneumatical test stand worked with a rotat…
Dynamische Analyse von Osteosynthesen am Olecranon: ein in-vitro Vergleich zweier Osteosynthesesysteme / Dynamic analysis of olecranon osteosyntheses…
2008
INTRODUCTION The aim of the present study was to develop a test setup with continuous angle alteration to imitate elbow joint motion for the mechanical evaluation of tension band wiring and a newly designed intramedullary nail. MATERIALS AND METHODS The servo-pneumatical test stand worked with a rotational angle-adjusted and a linear force-adjusted engine. The fracture model was dynamically tested under cyclic loading imitating elbow joint motion. In total, 14 fresh cadaver upper extremities underwent olecranon fracture by means of transverse osteotomy and were assigned to two groups: tension band wiring and intramedullary nailing. There was a continuous angle alteration between 0 and 1000 …